Glass roof

Glazed Atrium

Ukraine
Façade & roof glazing
Glazed Atrium
Location

Ukraine

Project type

Private architecture

Glazing solution

Inclined roof glazing

System / platform

Aluminium façade system

PROJECT STORY

Architecture first.

The difficult part of a glazed atrium is not the glass itself. Water requires more attention: how it moves down the inclined surface, what happens at the low point and how the glazed structure meets the roof.

The transparent volume sits between existing roof slopes. Geometry has to close correctly in several planes, while the interfaces still need to remain accessible for sealing and future inspection. That is why this type of structure has to be designed as part of the roof rather than as a large window placed above a room.

CASE STUDY

Three critical junctions

01

Inclined geometry

Mullions, transoms and infill planes have to meet the actual roof levels. Width and height alone are not enough; diagonals and real angles need to be checked before fabrication.

02

A continuous water path

Water is always moving on inclined glazing. It needs a continuous route out, without pockets where it can collect at the interface between the aluminium and the roof.

03

Roof interface

Metal, membranes, roof finishes and aluminium frames all move differently. The detail has to accommodate that movement while remaining weather-tight.

Why it is an engineered structure

A glazed atrium combines façade and roof logic. Structural behaviour, drainage, geometry and the interface with the main building are equally important.

TECHNICAL DETAILS

01 / SYSTEM

Aluminium roof & façade glazing

GALLERY

START A PROJECT

Planning a project?

Send architectural drawings, a specification or a few photographs. We will return with technical questions and propose the next step.

Discuss your project ↗